Previous Next
Sold on
25/10/22
Winning Offer
US $17,000
# of Offers
8
# of Watchers
8
SOLD!
ITEM DETAILS
Meter Reading
8,917 Hours
Serial #
Dual Controls, CAT 10-20B Diesel Heated 10 ft - 19 ft 6 in Screed

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
 
Model Description
Description Details


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Functional Operational Click here to open photos and videos of this item.  
(6)


Safety
Description Rating Details  
Horn Operational
Current Safety Manual No
Current Operator/Maintenance Manual No


Control Station - Paver
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Seats/armrests Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Powertrain controls Click here to open photos and videos of this item.  
Oil Pressure The gauge registers in the operating range. Click here to open photos and videos of this item.  
Engine Warning Lights Operational, Auger light flashes light stays on Click here to open photos and videos of this item.  
Screed Control Switches Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 8916.2 hrs, 8890.3 on Service meter. Click here to open photos and videos of this item.  
Hour Meter 8917 hrs, Operational hour meter, 8891.6 on Service meter. - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(20)


Engine
Description Rating Details  
Engine US EPA Label not legible
Blow-by Minor Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(6)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Left Drive Motor
Right Drive Motor
Left Final Drive Click here to open photos and videos of this item.  
Right Final Drive Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(2)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hydraulic Motors Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Hopper Wing Cylinders Click here to open photos and videos of this item.  
Screed Tow Point Cylinders Click here to open photos and videos of this item.  
Screed Lift Cylinders Click here to open photos and videos of this item.  
Screed Extension Cylinders Wet accumulation Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational. Screw lift cylinder leak.
(24)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Screed Serial Number Serial Number: BWN02345 Click here to open photos and videos of this item.  
Screed Lift Arms Click here to open photos and videos of this item.  
Screed Bottom Plate / Mat Click here to open photos and videos of this item.  
Hopper Wings Click here to open photos and videos of this item.  
Auger/ Screw Condition Click here to open photos and videos of this item.  
Feed Conveyors Heavy wear Click here to open photos and videos of this item.  
Conveyor Drive Chains and Sprockets Click here to open photos and videos of this item.  
Push Rollers Click here to open photos and videos of this item.  
Screed Heaters Not operationally checked Click here to open photos and videos of this item.  
Screed Slope Adjustment Powered adjustment, Operational Click here to open photos and videos of this item.  
Screed Crown Adjustment Powered adjustment, Operational Click here to open photos and videos of this item.  
Screed Tow Point Adjustment Powered adjustment, Operational Click here to open photos and videos of this item.  
Mat Thickness Adjusters Manual adjustment, Operational Click here to open photos and videos of this item.  
Extension Tubes Left tube chrome damaged. Click here to open photos and videos of this item.  
End Gates Click here to open photos and videos of this item.  
Spray Down System Click here to open photos and videos of this item.  
Limited Function Check The main components were operational in a limited check.
(34)


Undercarriage - Rubber Track
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Left Roller Frame Click here to open photos and videos of this item.  
Left Track Tensioner Click here to open photos and videos of this item.  
Left Track Belt Condition Damage to the inside of the track belts Click here to open photos and videos of this item.  
Left Rubber Belt Drive Lugs Worn/cracked Click here to open photos and videos of this item.  
Left Grouser Height 0 mm Click here to open photos and videos of this item.  
Left Track Rollers Click here to open photos and videos of this item.  
Left Front Idler Click here to open photos and videos of this item.  
Left Rear Idler Click here to open photos and videos of this item.  
Right Roller Frame Click here to open photos and videos of this item.  
Right Track Tensioner Click here to open photos and videos of this item.  
Right Track Belt Condition Damage to the inside of the track belts Click here to open photos and videos of this item.  
Right Rubber Belt Drive Lugs Worn/cracked Click here to open photos and videos of this item.  
Right Grouser Height 0 mm Click here to open photos and videos of this item.  
Right Track Rollers Click here to open photos and videos of this item.  
Right Front Idler Click here to open photos and videos of this item.  
Right Rear Idler Click here to open photos and videos of this item.  
(28)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Oct 05, 2022 Oct 05, 2022
Silicon 8.34 PPM 3.27 PPM
Tin 0 PPM 0 PPM
Silver 0.01 PPM 0 PPM
Aluminum 1.55 PPM 1.38 PPM
Chromium 0.1 PPM 0.12 PPM
Lead 0 PPM 0.89 PPM
Copper 0.59 PPM 0.2 PPM
Nickel 0.06 PPM 0.19 PPM
Iron 5.74 PPM 3.03 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.