Previous Next
Sold on
28/09/23
Winning Bid
US $21,000
# of Bids
SOLD!
ITEM DETAILS
Meter Reading
1,996 Hours
Serial #
Open Operator Station, Joystick Steering, 2016 US EPA Label, 18 in Track Belts, Manual Coupler, Bucket
***A bucket was installed post inspection***

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark No CE mark found
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Functional Operational Click here to open photos and videos of this item.  
(20)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Operational
Seat belts Operational
Safety lock out/stop Operational Click here to open photos and videos of this item.  
Current Safety Manual Yes
Current Operator/Maintenance Manual Yes
(2)


Control Station
Description Rating Details  
Seats/armrests Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Auxiliary Hydraulic Control Click here to open photos and videos of this item.  
Powertrain controls Click here to open photos and videos of this item.  
Dash Console Click here to open photos and videos of this item.  
Engine Oil Pressure No oil pressure indicator
Engine Warning Lights Operational, Warning light stays on Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 1996.0 hrs Click here to open photos and videos of this item.  
Hour Meter 1996 hrs, Operational hour meter - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check Would not restart after shutdown
(23)


Engine
Description Rating Details  
Engine 2016 US EPA Label
Emission Label Photo Click here to open photos and videos of this item.  
Blow-by Minor Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Not fully accessible Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting. Click here to open photos and videos of this item.  
(9)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors Wet Click here to open photos and videos of this item.  
Final Drives Wet Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(4)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Low fluid Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Auxiliary Hydraulic Plumbing Seepage Click here to open photos and videos of this item.  
Loader Lift Cylinders Right side seepage Click here to open photos and videos of this item.  
Bucket Tilt Cylinders Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(12)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Frame Condition Click here to open photos and videos of this item.  
Belly pans Click here to open photos and videos of this item.  
Lift Arm Condition Significant denting near coupler Click here to open photos and videos of this item.  
Chassis to Arm Pins Click here to open photos and videos of this item.  
Coupler to Arms Pins Click here to open photos and videos of this item.  
Limited Function Check The main chassis components were operational in a limited check.
(13)


Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Roller Frames Click here to open photos and videos of this item.  
Grouser Height Measurement Left side: 16 mm, Right side: 14 mm
Track Belt Condition Cuts and damage Click here to open photos and videos of this item.  
Rubber Belt Drive Lugs No visible damage Click here to open photos and videos of this item.  
Track Tensioners Operational
Front Idler wear Click here to open photos and videos of this item.  
Rear idler wear Click here to open photos and videos of this item.  
Track Rollers Click here to open photos and videos of this item.  
Sprockets Click here to open photos and videos of this item.  
(23)


Specialty
Description Rating Details  
Quick Connect Operational Click here to open photos and videos of this item.  
Loader Bucket Condition No bucket included
(5)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Oct 27, 2022 Oct 27, 2022
Silicon 11.54 PPM 18.21 PPM
Tin 0 PPM 0 PPM
Silver 0 PPM 0 PPM
Aluminum 3.66 PPM 11.4 PPM
Chromium 0.25 PPM 0.42 PPM
Lead 0 PPM 0.26 PPM
Copper 1.53 PPM 9.25 PPM
Nickel 0.8 PPM 0.46 PPM
Iron 12.61 PPM 50.18 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.