ITEM DETAILS
Meter Reading
3,221 Hours
Serial #
No Title Available, 82 Ton Capacity, Main & Auxiliary Hoist Drums, 120' Main Boom, Detroit Diesel Carrier Engine, Detroit Diesel Upper Engine

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Motor Vehicle Safety Standards Label No
Safety Certification Label Click here to open photos and videos of this item.  
Safety Certification Report Safety Certification Report Not Available
Load Chart Yes Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet metal (fiberglass) condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Functional Not operational Click here to open photos and videos of this item.  
(35)


Safety
Description Rating Details  
Travel Alarm Inoperable
Horn Inoperable
Seat belts Inoperable
Current Safety Manual No
Current Operator/Maintenance Manual Yes


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Mirrors Click here to open photos and videos of this item.  
Seats/armrests Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Steering Controls Heavy steering wheel play Click here to open photos and videos of this item.  
Powertrain controls Click here to open photos and videos of this item.  
Oil Pressure Gauge inoperable Click here to open photos and videos of this item.  
Gauges Tachometer, engine oil & engine coolant temperature gauges are inoperable Click here to open photos and videos of this item.  
Hour Meter/Odometer (Start) 28,857.8 Miles Click here to open photos and videos of this item.  
Hour Meter/Odometer 28,857.9 Miles; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(16)


Carrier/Chassis Engine
Description Rating Details  
Make and Model Make: Detroit ; 8 Cylinder Engine
Fuel Type Diesel
Emission Control Label None found Click here to open photos and videos of this item.  
Blow by @ idle (subjective observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Turbo or Blower No visible damage Click here to open photos and videos of this item.  
Injector pump Operational Click here to open photos and videos of this item.  
Exhaust System Some joints/connnections have a visible leak. Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks Side of engine; Rear of engine; Oil Pan; Valve cover Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Air Compressor Operational
Limited Function Check The engine started and ran. The engine is difficult to shut down.
(12)


Underbody
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Type Manual; 9 speed transmission
Transmission Operational; Dripping leak Click here to open photos and videos of this item.  
Clutch Engages
PTO Pump Dripping leak; Operational Click here to open photos and videos of this item.  
Front Axle Dripping Leak Click here to open photos and videos of this item.  
Rear Axle Click here to open photos and videos of this item.  
Axle Bump Stops Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check - Carrier The drivetrain was operational without a load.
(9)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Steering Linkage Click here to open photos and videos of this item.  
Steering Wheel Play Heavy movement
Brake Type Air
Master Cylinder/Brake Control Click here to open photos and videos of this item.  
Brake Lines/Hoses
Park Brake Held against power; Stopped the machine while rolling Click here to open photos and videos of this item.  
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine. The air system has an audible air leak after shut down.
Springs/Hangers Condition Click here to open photos and videos of this item.  
External Electrical / Air Connections Not operationally checked Click here to open photos and videos of this item.  
Frame Condition Click here to open photos and videos of this item.  
Cross Members Some steel has signs of weld repair. Click here to open photos and videos of this item.  
Tire Size Click here to open photos and videos of this item.  
Tyre Condition Click here to open photos and videos of this item.  
Tread Depth LF 13,23 /32"; LMI 1 /32"; LMO 8 /32"; LRI 19 /32"; LRO 22 /32"; RRI 23 /32"; RRO 22 /32"; RMI 23 /32"; RMO 23 /32"; RF 18,17 /32"
Wheel Condition
Wheel Studs
Outrigger Beams Click here to open photos and videos of this item.  
Outrigger Cylinders Dripping leak on the left rear cylinder; Dripping leak on the right rear cylinder Click here to open photos and videos of this item.  
Outrigger Pads Click here to open photos and videos of this item.  
(35)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Dripping leak; The carrier PTO pump has a dripping leak. Click here to open photos and videos of this item.  
Valves Dripping leak Click here to open photos and videos of this item.  
Hydraulic Tank Dripping leak Click here to open photos and videos of this item.  
Hoses (Hydraulic) Some lines/fittings have a dripping leak. Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(8)


Control Station - Crane Lattice Boom
Description Rating Details  
Mirrors Click here to open photos and videos of this item.  
Glass Some seals are damaged. Click here to open photos and videos of this item.  
Seats/armrests Click here to open photos and videos of this item.  
Controls Hydraulic or Air Click here to open photos and videos of this item.  
Load Charts Posted on cab wall Click here to open photos and videos of this item.  
Oil Pressure Intermittently not reading
Gauges The guages would intermittently not respond Click here to open photos and videos of this item.  
Hoist Brakes Click here to open photos and videos of this item.  
Hour Meter/Odometer (Start) 3,221.5 Hours Click here to open photos and videos of this item.  
Hour Meter/Odometer 3,221.5 Hours; Inoperable hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Control labels are not legible. Click here to open photos and videos of this item.  
(18)


Upper Engine
Description Rating Details  
Make and Model Make: Detroit
Fuel Type Diesel
Emission Control Label None found
Blow by @ idle (subjective observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Turbo or Blower Dripping Leak Click here to open photos and videos of this item.  
Injector pump Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks Side of engine; Oil Pan Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Limited Function Check The engine started and ran.
(11)


Crane Superstructure
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Hoist and Boom Drums Mechanical Draw Works; Could not be operationally checked. Click here to open photos and videos of this item.  
Boom Drums Mechanical Draw Works Click here to open photos and videos of this item.  
Hoist and Boom Clutches Click here to open photos and videos of this item.  
Main Boom Pins Click here to open photos and videos of this item.  
Point Sheaves Click here to open photos and videos of this item.  
Boom Point Section Click here to open photos and videos of this item.  
Boom Stops Click here to open photos and videos of this item.  
Boom Length 120' Overall length Click here to open photos and videos of this item.  
Turn-table Bearing Click here to open photos and videos of this item.  
Bottom Covers Click here to open photos and videos of this item.  
Swing Drive Operational Click here to open photos and videos of this item.  
Limited Function Check The main chassis components functioned when checked without a load.
(28)
 

Oil Sample Analysis
  engine engine2
date of analysis Oct 03, 2019 Oct 03, 2019
Silicon 0 PPM 0 PPM
Tin 0 PPM 0 PPM
Silver 0 PPM 0 PPM
Aluminum 0 PPM 0 PPM
Chromium 0.28 PPM 0 PPM
Lead 0 PPM 17.23 PPM
Copper 0.25 PPM 14.32 PPM
Nickel 0 PPM 0 PPM
Iron 8.21 PPM 18.5 PPM
Glycol NEG NEG
Water NEG NEG
Fuel <5% <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.