Previous Next
Auction Closed on
16/07/26
Asking Price
US $178,900
NOT SOLD
ITEM DETAILS
Meter Reading
1,884 Hours
Serial #
1883 Machine Hours Showing, Hydrostatic, Air Conditioner, Raven Display, Raven Antenna/ Receiver, Requires Diesel Exhaust Fluid, Agco Air Max 10 ft 6 in, 60/40 Dual Bin Box, Electric Tarp, 380/90R46, 380/90R46 Rear Tires, Dual Bin, Tarp

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Hour Meter / Odometer 1884 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet metal (fiberglass) condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Exterior Lights Functional Operational Click here to open photos and videos of this item.  
(20)


Control Station
Description Rating Details  
(1)


Safety
Description Rating Details  
Travel Alarm Inoperable
Horn Inoperable
Seat belts Operational
Current Safety Manual Yes
Current Operator/Maintenance Manual Yes


Control Station
Description Rating Details  
Mirrors Click here to open photos and videos of this item.  
Seats/armrests Click here to open photos and videos of this item.  
Passenger seat Yes Click here to open photos and videos of this item.  
Hydraulic Controls Not operationally checked Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Powertrain controls Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Engine Warning Lights Inoperable, Check engine light stays on Click here to open photos and videos of this item.  
Gauges Operational
Cab Air Conditioner The ambient temperature is too cold to check
Cab Heater Operational
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(8)


Engine
Description Rating Details  
Engine Requires Diesel Exhaust Fluid
Air Conditioning Compressor In place; ambient temperature too cold to check operation Click here to open photos and videos of this item.  
Blow-by No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
DEF / AdBlue Tank Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(8)


Drivetrain - Small
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational Click here to open photos and videos of this item.  
Drive/propel motors Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(9)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Hydraulic Motors Not operationally checked Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Cylinder(s) Click here to open photos and videos of this item.  
Cylinder Pins and Bushings
Limited Function Check The hydraulic system was operational. Hydraulic cooler is very rusty and is seeping.
(10)


v2 Chassis - Spreader
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
(14)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Granular Bins Number of Bins 2, Could not check sensors Click here to open photos and videos of this item.  
Fans and Manifold Click here to open photos and videos of this item.  
Product Tubes Click here to open photos and videos of this item.  
Conveyor Click here to open photos and videos of this item.  
Controller Appears complete, Make and Model Raven Click here to open photos and videos of this item.  
Steering Linkage Click here to open photos and videos of this item.  
Brake Type Hydraulic, Air
Master Cylinder/Brake Control
Brake Control Click here to open photos and videos of this item.  
Brake Lines/Hoses Not operationally checked
Park Brake Stopped from a slow roll
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.
Frame Condition Click here to open photos and videos of this item.  
Left Front Tire Click here to open photos and videos of this item.  
Left Rear Tire Click here to open photos and videos of this item.  
Right Rear Tire Click here to open photos and videos of this item.  
Right Front Tire Click here to open photos and videos of this item.  
Tread Depth LF 24/32", LR 28/32", RR 28/32", RF 28/32"
Wheel Condition
Wheel Studs, Nuts, Lugs
(12)
 

Oil Sample Analysis
  engine
date of analysis Apr 21, 2026
Silicon 0.63 PPM
Tin 0.32 PPM
Silver 0.08 PPM
Aluminum 0.86 PPM
Chromium 0.22 PPM
Lead 4.12 PPM
Copper 1.56 PPM
Nickel 0.29 PPM
Iron 15.34 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.