Previous Next
Ends
Subject to Offers
 
  
Buy Now Price
CAD 20,000
You will confirm this action on the next page. How it works. How Make Offer works.
ITEM DETAILS
Meter Reading
5,573 Hours
Serial #
Enclosed Cab, Air Conditioner, Pressurized Cab, Cat C15 Diesel Engine, Cubex 13 ft Boom, 32 ft 6 in Mast, Cubex Hammer, Rod Changer, ( 6 ) 4 in Drill Rods, 20 in Triple Grouser Track Shoes
**Engine has been removed from sale item as it is scheduled for rebuild, Not able to operationally check**

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Paint in good shape for its age Worn off is some spots Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Original tin work is in good condition Make shift winter shelter on unit for cold weather drilling is in rough shape Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Exterior Lights Functional Unit has no engine in it as it is out of unit for rebuild
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
(18)


Safety
Description Rating Details  
Travel Alarm Could not check due to engine is removed for rebuild
Horn Could not check due to engine is removed for rebuild
Seat belts Operational
Current Safety Manual Yes
Current Operator/Maintenance Manual Yes


Control Station
Description Rating Details  
Seats/armrests Click here to open photos and videos of this item.  
Steering Controls Could not check due to engine is out of unit for rebuild Click here to open photos and videos of this item.  
Hydraulic Controls Could not check due to engine is out of unit for rebuild Click here to open photos and videos of this item.  
Powertrain controls Could not check due to engine is out of unit for rebuild Click here to open photos and videos of this item.  
Dash Console Click here to open photos and videos of this item.  
Engine Oil Pressure Could not check due to engine is out of unit for rebuild Click here to open photos and videos of this item.  
Engine Warning Lights Could not check due to engine is out of unit for rebuild Click here to open photos and videos of this item.  
Gauges Could not check due to engine is out of unit for rebuild Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 5573 hrs, Could not verify hours Click here to open photos and videos of this item.  
Hour Meter 5573 hrs, Could not check due to engine is out of unit for rebuild - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Cab Air Conditioner Could not check due to engine is out of unit for rebuild
Cab Heater Not operationally checked
Limited Function Check The item was not operational. Ratings are based on a static inspection.
(11)


Engine
Description Rating Details  
Air Conditioning Compressor Unit was removed from engine so engine could be removed to send out for rebuild Click here to open photos and videos of this item.  
Blow-by Engine is out of unit for rebuild
Starter Not operationally checked
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Coolant system is empty due to engine is out of unit for rebuild purposes Click here to open photos and videos of this item.  
Engine - Left Side Engine is out of unit for rebuild Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check Engine is out of unit for rebuild purposes
(8)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Service Brakes Could not check due to engine is out of unit for rebuild purposes
Drive Motors Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check (Drivetrain-Track) The drivetrain could not be operationally checked.
(4)


Hydraulics
Description Rating Details  
Pumps (Hydraulics) Pumps have been removed due to engine rebuild
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Boom Lift Cylinder(s) Click here to open photos and videos of this item.  
Stabilizer Cylinders Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system could not be operationally checked.
(9)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Boom Condition Click here to open photos and videos of this item.  
Mast Condition Click here to open photos and videos of this item.  
Main Frame Click here to open photos and videos of this item.  
Bottom Covers Are removed for engine rebuild Click here to open photos and videos of this item.  
Thrust Chain / Sprockets Click here to open photos and videos of this item.  
Kelly Drive Gear Box Click here to open photos and videos of this item.  
Kelly Slide Wear Plates Click here to open photos and videos of this item.  
Hyd. Hose Carrier System Click here to open photos and videos of this item.  
Vices Click here to open photos and videos of this item.  
Drill Rod Loading System Could not be operationally checked Click here to open photos and videos of this item.  
Drill Rod Racks Click here to open photos and videos of this item.  
Air Compressor Not operationally checked Click here to open photos and videos of this item.  
Limited Function Check The unit could not be started and run; several components could not be checked.
(13)


Undercarriage
Description Rating Details  
Left Roller Frame Click here to open photos and videos of this item.  
Left Track Tensioner Click here to open photos and videos of this item.  
Left Track Pads Click here to open photos and videos of this item.  
Left Grouser Height 16 mm Click here to open photos and videos of this item.  
Left Track Links Click here to open photos and videos of this item.  
Left Track Bushings Bushings have not been turned Click here to open photos and videos of this item.  
Left Carrier Rollers Click here to open photos and videos of this item.  
Left Track Rollers Click here to open photos and videos of this item.  
Left Idler Click here to open photos and videos of this item.  
Left Sprocket Click here to open photos and videos of this item.  
Right Roller Frame Click here to open photos and videos of this item.  
Right Track Tensioner Click here to open photos and videos of this item.  
Right Track Pads Click here to open photos and videos of this item.  
Right Grouser Height 19 mm Click here to open photos and videos of this item.  
Right Track Links Click here to open photos and videos of this item.  
Right Track Bushings Bushings have not been turned Click here to open photos and videos of this item.  
Right Carrier Rollers Click here to open photos and videos of this item.  
Right Track Rollers Click here to open photos and videos of this item.  
Right Idler Click here to open photos and videos of this item.  
Right Sprocket Click here to open photos and videos of this item.  
(22)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.