Previous Next
Sold on
13/02/24
Winning Offer
US $330,000
# of Offers
# of Watchers
47
SOLD!
ITEM DETAILS
Meter Reading
See Report
Serial #
Enclosed Cab, Air Conditioner, Cummins QSK19 6 Cylinder Diesel Engine, Hydrostatic Drive, 950 mm Wide x 12000 mm Long Discharge Conveyor, 765 mm Double Grouser Track Shoes
**GCC DUTY PAID**

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
 
Model Description
Description Details


General Appearance
Description Rating Details  
CE Mark CE Marked Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Functional Some not operational, lower front LHS lights are not operational Click here to open photos and videos of this item.  
General Appearance #17 Click here to open photos and videos of this item.  
General Appearance #18 Click here to open photos and videos of this item.  
(13)


Safety
Description Rating Details  
Travel Alarm Missing
Horn Missing
Seat belts Not equipped
Current Safety Manual No
Current Operator/Maintenance Manual No
(2)


Control Station
Description Rating Details  
Steering Controls Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Powertrain controls Click here to open photos and videos of this item.  
Dash Console Click here to open photos and videos of this item.  
Engine Oil Pressure The fault indicator remains on after engine is started. Click here to open photos and videos of this item.  
Engine Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 4791.3 hrs Click here to open photos and videos of this item.  
Hour Meter 0 See Report, Inoperable hour meter - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Cab Air Conditioner Inoperable
Cab Heater Not operationally checked
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(10)


Engine
Description Rating Details  
Air Conditioning Compressor Operational Click here to open photos and videos of this item.  
Blow-by Visible Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check After jump starting, the engine ran. Click here to open photos and videos of this item.  
(19)


Drivetrain
Description Rating Details  
(9)


Drivetrain - Limited
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors Covered Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(3)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Dripping leak Click here to open photos and videos of this item.  
Hydraulic Motors Click here to open photos and videos of this item.  
Valves Dripping leak Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
Hydraulics #22 Click here to open photos and videos of this item.  
Hydraulics #23 Click here to open photos and videos of this item.  
(23)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Cutting Bits Click here to open photos and videos of this item.  
Roller Bushings Click here to open photos and videos of this item.  
Chain / Sprocket Condition Click here to open photos and videos of this item.  
Bar Idler Click here to open photos and videos of this item.  
Limited Function Check The main chassis components were operational in a limited check.
Park Brake Stopped from a slow roll
Limited Function Check - Brakes The service brakes were operational.
Frame Condition Click here to open photos and videos of this item.  
Cutting Bits Click here to open photos and videos of this item.  
(23)


Undercarriage
Description Rating Details  
Grouser Height Measurement Left side: 40 mm, Right side: 45 mm
Track Tensioners No visible damage
Front Idler wear Click here to open photos and videos of this item.  
Track Rollers Click here to open photos and videos of this item.  
Sprockets Click here to open photos and videos of this item.  
Track Tensioners No visible damage
Shoe Width 765 mm track shoes Click here to open photos and videos of this item.  
Grouser Height Left Side: 40 mm, Right Side: 45 mm Click here to open photos and videos of this item.  
Track link wear Click here to open photos and videos of this item.  
Pins and Bushings Rotated? No Click here to open photos and videos of this item.  
Track rollers wear No damage Click here to open photos and videos of this item.  
Idlers Click here to open photos and videos of this item.  
Sprockets Click here to open photos and videos of this item.  
(19)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.