Previous Next
Ends
3 days, 9 hours (Subject to early close)
Jan 2, 15:07 PM IST
 
  
You will confirm this offer on the next page. How Make Offer works. How Make Offer works.
ITEM DETAILS
Meter Reading
39,724 Hours
Serial #
Enclosed Cab, Exhaust Heated Bed, Retarder, 18.00R33 Tires

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
 
Tires
Front Axle  Tire Size: 18.00R33
Rear Axle  Tire Size: 18.00R33


General Appearance
Description Rating Details  
Paint Fully Resprayed Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Weld repairs visible throughout Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Some not operational Click here to open photos and videos of this item.  
(23)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Missing
Seat Belts Operational


Control Station
Description Rating Details  
Mirrors Click here to open photos and videos of this item.  
Steering Control Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises. Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational; Click here to open photos and videos of this item.  
Hour Meter/Odometer (Start) 39723.8 Hours Click here to open photos and videos of this item.  
Hour Meter/Odometer 39724.2 Hours - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Air Conditioner The fan is inoperable
Heater Controls inoperable
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(18)


Engine
Description Rating Details  
A/C Compressor Fan inoperable. Click here to open photos and videos of this item.  
Blow by @ idle (subjective visual observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) The engine started and ran. Click here to open photos and videos of this item.  
(10)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational; Only one forward gear operational. Click here to open photos and videos of this item.  
Transfer Case / Drop Box Operational Click here to open photos and videos of this item.  
Steer Axle Click here to open photos and videos of this item.  
Rear Drive Axle Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(12)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Cylinders Slight movement. Click here to open photos and videos of this item.  
Steering Cylinders Very slight drip right side. Steering heavy. Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(27)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Oscillating Hitch Click here to open photos and videos of this item.  
Frame Condition Click here to open photos and videos of this item.  
Suspension Cylinders Front left cylinder leaking oil and inoperable. Click here to open photos and videos of this item.  
Suspension Pivot Points Click here to open photos and videos of this item.  
Limited Function Check The main chassis components functioned during a limited check.
Master Cylinder/Brake Control Click here to open photos and videos of this item.  
Brake Lines/Hoses
Park Brake Stopped from a slow roll
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.; The park brake is operational
Left Front Steer Tire Cheat; 40mm Click here to open photos and videos of this item.  
Left Rear Drive Tire Toyo; 35mm Click here to open photos and videos of this item.  
Right Rear Drive Tire Toyo; 30mm Click here to open photos and videos of this item.  
Right Front Steer Tire Toyo; 30mm Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs, Nuts, Lugs
(27)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Bed Body Click here to open photos and videos of this item.  
Bed Pads Click here to open photos and videos of this item.  
Hinge Points Click here to open photos and videos of this item.  
Limited Function Check The main chassis components were operational in a limited check.
(15)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.